<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-20 14-50-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 41 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
5 kHz 9 kHz 18355 0,0654
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,7 dBr -1,06 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 14:49, 20.05.2024
RT
"Bruselske chlebicky - Kdo vede evropske politicke strany do c..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 9 kHz MIN: 5 kHz % above 77 kHz: 0,0654 Acquired: 2024/05/20 14:50:01 Total samples: 18355 Equivalent time: 0:15:17 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,1 dBr MIN: -1,7 dBr AVE: -1,06 dBr % above 0,2 dBr: 0,0 Last value: -1,0 dBr (2024/05/20 14:50:01) 14:36 14:38 14:40 14:42 14:44 14:46 14:48 14:50 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality